This is an alert about new products, services, trainings, jobs, weather, sales, holidays, closings, etc.
AMP | : | 20 A (Max Fuse) |
BTU Cooling Rating | : | 18,000 Btu/hr |
Blower Diameter | : | 23 in |
Blower Motor Type | : | PSC |
Capacity (Kg) | : | 1524.07 |
Charging Specification Subcooling | : | 9 deg F |
Compressor Insulation/Sound Blanket | : | No |
Compressor LRA | : | 47.5 |
Compressor RLA | : | 7.8 |
Compressor Stages | : | Single Stage |
Compressor Sump Heater Factory Installed | : | No |
Compressor Type | : | Scroll |
EER2 | : | 11.7 |
Elec Hertz | : | 60 Hz |
Elec Phases | : | 1 ph |
Elec Volts | : | 208/230 V |
Fin Type | : | Spine Fin |
Full Load Amperage (FLA) | : | 0.64 |
Fuse Rating | : | 20 A |
HSPF2 Range | : | 8.1 |
HSPF2 | : | 7.5-8.1 |
HSPF | : | 8.1 BTU/watt-hr |
Line Size - Liquid (in) | : | 5/16 |
Line Size - Suction (In) | : | 3/4 |
MCA | : | 12 |
Max Fuse | : | 20 A |
Model | : | 5TWR5 |
Motor Speed | : | 850 rpm |
Noise Level | : | 71 dba |
Number of Fans | : | 1 |
Number of Stages | : | Single |
Phase | : | 1.0 ph |
Power Supply | : | 208/230 V/1 Phase/60 Hz |
Product Family Series | : | 15 Single-Stage Heat Pump |
Refrigerant Control | : | TXV |
Refrigerant Type | : | R-454B |
Rows - Fins per Inch | : | 1 - 24 |
SEER Rating | : | 15.2 |
SEER2 Range | : | 8.1 |
SEER | : | 15 |
Series | : | 14 Single Stage Heat Pump |
Sound Rating (dB) | : | 71 dBA |
Specifications - UL Listed | : | Yes |
Stage | : | 1 |
Tonnage | : | 1 Ton |
Tonnage | : | 1.0 Ton |
Tube Size (In) | : | 3/8 |
Type | : | Split System Heat Pump |
Volts | : | 208/230 V |
Trane 5TWR5018A1000A, 15 Single-Stage Heat Pump, 1.5T, 15.2 SEER2 , 18,000 BTU, 208/230V, R454B, 8.1 HSPF
15 SEER2 heat pumps meet 2025 Low Global Warming Potential (Low GWP) regulatory criteria using R-454B refrigerantNew TXV and refrigeration designs that are optimized for maximum performance using the new refrigerantCompatibility with existing accessories and kitsUnit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test.The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise.The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panelsRefrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard.