This is an alert about new products, services, trainings, jobs, weather, sales, holidays, closings, etc.
American Standard 5WCC4060A1000A, Choice , 5T, 13.6 SEER2, Single Stage Heat Pump Package Unit
American Standard 5WCC4060A1000A, Choice , 5T, 13.6 SEER2, Single Stage Heat Pump Package Unit
Manufacturer: Trane International Inc
Brand: American Standard®
Part #: 390620
MPN: 5WCC4060A1000A
Customer Part #:
Min. Order Qty: 1
Login for Availability
Login for Price
Additional Information | : | SEER2: 13.6|Sound Rating (dB): 77.3|Subcooling Temperature: 8 deg F |
Airflow CFM | : | 1700 |
BTU Cooling Rating | : | 60,000 Btu/hr |
CFM Rating | : | 2,000 cfm |
Compressor LRA | : | 150 |
Compressor Power Rating | : | 208/230 V/1 Phase/60 Hz |
Compressor RLA | : | 25.6 |
Compressor Stages | : | Single Stage |
Compressor Type | : | Scroll |
Cooling Capacity (BtuH) | : | 58000 |
Crated Dimensions (H X W X D) | : | 52 x 47 x 62 in |
EER2 | : | 11 |
Filter Furnished | : | No |
Filter Type Recommended | : | Throwaway |
Filter-Face Area sq-ft | : | 5.3 |
Fuse Rating | : | 60 A |
HSPF Rating | : | 7.0 |
HSPF2 Range | : | 14 |
HSPF2 | : | 7 |
Heating Power Input (W) | : | 4780/4360 (High/Low Temp) |
Heating: Capacity BTUH (High/Low Temp) | : | 56000/34800 |
Indoor Coil-Drain Connection Size | : | 3/4 in NPT |
Indoor Coil-FPI | : | 15 |
Indoor Coil-Face Area sq-ft | : | 5 |
Indoor Coil-Rows | : | 4 |
Indoor Coil-Type | : | Plate Fin |
Indoor Coil: Tube Size (In.) | : | 0.375 |
Indoor Fan Type | : | Constant Torque ECM |
Indoor Fan-Dia x W in | : | 11.87 x 10.62 |
Indoor Fan-Number of Speeds | : | 4 |
Indoor Fan: Motor HP (Standard/Oversized) | : | 1 |
Indoor Unit: Fan Motor FLA | : | 7.4 |
Indoor Unit: Fan Motor Speed RPM | : | 1050 |
MCA | : | 41 |
Max Fuse | : | 60 A |
Model | : | 5WCC |
Motor Type | : | ECM |
Nominal Capacity | : | 5.0 Ton |
Number of Stages | : | Single |
Outdoor Coil-FPI | : | 24 |
Outdoor Coil-Face Area sq-ft | : | 23 |
Outdoor Coil-Rows | : | 2 |
Outdoor Coil-Tube Size (In) | : | 3/8 |
Outdoor Coil-Type | : | Spine Fin |
Outdoor Coil: Refrigerant Control | : | Expansion Valve |
Outdoor Fan - CFM | : | 5500 |
Outdoor Fan - Diameter In | : | 28.25 |
Outdoor Fan - Drive | : | Direct |
Phase | : | 1.0 ph |
Refrigerant Type | : | R-454B |
SEER Rating | : | 13.6 |
Series | : | Choice |
Sound Level | : | 77 dBA |
American Standard 5WCC4060A1000A, Choice , 5T, 13.6 SEER2, 60,000 BTU Cooling, 208/230V, 7.0 HSPF, R454B, TXV Metering, ECM Motor, Single Stage Heat Pump Package Unit
Single stage scroll compressorAll components shall be mounted in a weather-resistant steel cabinet with an enamel finish. Access panels shall be provided for unit controls and indoor coil and fans. IThe compressor shall be hermetically sealed, high efficiency scroll compressors. Internal overcurrent and over temperature protection, internal pressure relief shall be standard. Other features include centrifugal oil pump, low vibration and noise.All units shall have refrigerant control. Service pressure tap ports and a refrigerant line filter shall be standard.All units have TXV to control refrigerant flow.The Spine Fin ™ condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints.Constant Torgue, forward-curved, centrifugal wheel in a Composite Vortica ® Blower housing.Lower global warming potential R-454B refrigerant